phone Phone
+62215660420
close
menu

PT. Lienetic Jaya

sql
Schneider SAMWHA EOCR 3DM2-WRDUW
Hover to Zoom

Jual Schneider SAMWHA EOCR 3DM2-WRDUW



Spesifikasi Schneider SAMWHA EOCR 3DM2-WRDUW

Schneider Electric model EOCR-3DM2-WRDUW, distributor resmi di Indonesia.

  • Part Number : 3DM2WRDUW
  • Range of product : EOCR
  • Device short name : EOCR-3DM2
  • Product or component type : Protection relay
  • Protection type :
  • Overload, In > OC setting
  • Underload, In < UC setting
  • Locked rotor for starting, In > 2…8 times OC setting
  • Locked rotor for running, In > 1.5…5 times OC setting
  • Sensitivity to phase loss
  • Phase unbalance, 10…50 %
  • Sensitivity to phase reverse
  • Product specific application : Motor protection
  • Network type : AC
  • Network frequency : 50…60 Hz
  • Protection adjustment range : 0.5…60 A
  • Tripping threshold :
  • 0.5…32 A (inverse and thermal)
  • 0.5…60 A (definite)
  • [Us] rated supply voltage : 100…240 V AC/DC
  • Mounting support : Panel (35 mm DIN rail)
  • Contacts type and composition :
  • 1 NC + 1 NO (OL)
  • 1 NO (AL/UL/TO)
  • Short-circuit and overload protection : By 4 A gG fuse
  • [Ue] rated operational voltage :
  • Power circuit : 600 V AC 50…60 Hz UL
  • Power circuit : 690 V AC 50…60 Hz CSA
  • Power circuit : 690 V AC 50…60 Hz IEC 60947-4-1
  • [Uimp] rated impulse withstand voltage : 6 kV IEC 60947-4-1
  • Reset :
  • Electrical 0…1 s by interruption of power supply
  • Manual reset
  • Automatic reset 0.5…1200 s
  • Time delay type :
  • D-Time : 0…200 s
  • O-Time : 0.2…30 s (definite)
  • O-Time : 1…30 class (inverse and thermal)
  • U-Time : 0.5…30 s
  • Display type :
  • 7 segments LED
  • Bar graph
  • Power consumption per relay : < 3 W
  • Connections – terminals :
  • Control circuit : 2 cable 1…1.5 mm² – flexible – with cable end – M3
  • Control circuit : 2 cable 1…1.5 mm² – flexible – without cable end – M3
  • Control circuit : 1 cable 1…2.5 mm² – flexible – with cable end – M3
  • Control circuit : 1 cable 1…2.5 mm² – flexible – without cable end – M3
  • Tightening torque : 0.8…1.2 N.m for control circuit – cable – 4.7 mm head
  • Standards : IEC 60947-4-1
  • Product certifications : UL
  • IP degree of protection : IP20 IEC 60529
  • Ambient air temperature for operation : -20…60 °C IEC 60947-4-1
  • Ambient air temperature for storage : -40…85 °C
  • Operating altitude : 2000 m
  • Fire resistance :
  • 650 °C IEC 60695-2-12
  • 960 °C UL 94
  • Shock resistance : 15 gn for 11 ms IEC 60068-2-7
  • Vibration resistance :
  • 4 gn on panel mounting IEC 60068-2-6
  • 2 gn on 35 mm DIN rail IEC 60068-2-6
  • Dielectric strength :
  • 2 kV at 50…60 Hz in between case and circuit IEC 60255-5
  • 1 kV at 50…60 Hz in between contact IEC 60255-5
  • 2 kV at 50…60 Hz in between circuit IEC 60255-5
  • Surge withstand : 6 kV IEC 61000-4-5
  • Electromagnetic compatibility :
  • Resistance to electrostatic discharge 8 kV air, 6 kV contact IEC 61000-4-2
  • Resistance to radiated electromagnetic fields 10 V/m level 3 IEC 61000-4-3
  • Resistance to fast transient 2 kV IEC 61000-4-4
  • Conducted RF disturbances 10 V EN 61000-4-6
  • Conducted RF disturbances class A EN 55011
  • [Ith] conventional free air thermal current : 3 A, control circuit
  • Permissible current : 250 V, 3 A AC

 

Untuk keterangan lebih lanjut, silahkan download PDF ini :

phoneHubungi Kami